Phidget Motor Velocity Controller.lvlib:MotorVelocityControllerSetKp.vi

Proportional gain constant. A small MotorVelocityControllerKp value will result in a less responsive controller, however, if MotorVelocityControllerKp is too high, the system can become unstable.


For more information about MotorVelocityControllerKp, visit our MotorVelocityController API Guide

Phidget Motor Velocity Controller.lvlib:MotorVelocityControllerSetKp.vi

cu64

Device In

Device # Identification

cerrcodeclst

error in (no error)

error in can accept error information wired from VIs previously called.

cdbl

Kp

The Kp value.

DCC1020_0 (ver: 103) Velocity Controller: Default: 0.0001

DCC1120_0 (ver: 104) Velocity Controller: Default: 0.0001

iu64

Device Out

Same as Device In

ierrcodeclst

error out

error out passes error or warning information out of a VI to be used by other VIs.